Wateq 2023 - Flipbook - Page 147
CLACK VALVES
CLACK WS1.5 CI SOFTENER / FILTER VALVE
CLACK WS1.5 CI SPECIFICATIONS
Inlet/Outlet (1)
1 ½” Female BSPT or NPT
Cycles
up to 9
Valve Material
Lead free brass
Regeneration
downflow
CONTROL VALVE FLOW RATES
Service @ 1 bar/15 psi drop (includes meter)
265 lpm (15.9 m3/h) (70 gpm)
Backwash @ 1.7 bar/25 psi drop
197 lpm (11.8 m3/h) (52 gpm)
OPERATING PRESSURES
Minimum / Maximum
20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum / Maximum
4º- 43 ºC (40ºC - 110ºF)
METER
Accuracy
± 5%
Flow Rate Range
2 - 284 lpm (0.5 - 75 gpm)
Volume Range
0.02 - 5,700 m3
Totalizer
1 – 99,999 m3 (264 - 26,417,000 gallons
DIMENSIONS & WEIGHT
Distributor Pilot
Valve bodies with 1.5" Female BSPT Inlet & Outlet
50 mm OD
Valve bodies with 1.5" Female NPT Inlet & Outlet
1.90” OD (1.5" NPS)
Drain Line Connection (2)
1 ¼” Female NPT
Adapter Included
¾" Male NPT Elbow
Brine Line Connection
¾” Female NPT
Adapter Included
½” OD Poly Tube Compression
Mounting Base
4" - 8 UN
Height From Top Of Tank
191 mm (7.5”)
Shipping Weight With Meter
9.5 kg (21 lbs.)
ELECTRICAL SPECIFICATIONS
Supply Voltage
200VAC to 240VAC
Supply Frequency
50/60 Hz
Output Voltage
15VDC
Output Current
500 mA
TANK APPLICATIONS
Water Softener
12” - 30" Diameter (4)
Water Filter (3)
12” - 30" Diameter
CYCLES OF OPERATION
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Cycle
Range of times minutes
Backwash
1 - 120 minutes
Rinse
1 - 120 minutes
Pause (service)
1 - 480 minutes
Brine (co-current)
1 - 180 minutes
Refill (softener)
0.05 - 90.00 Kg
Refill (filter)
0.2 - 76.00 Litres
1. See Distributor Pilot. 2. Casting comes with a 1.25" Female NPT drain connection. An adapter is provided to accept existing WS1 drain line 3⁄4" Male NPT flow
controls up to 38 lpm (10 gpm). Other drain line flow controls are available for flow rates above 38 lpm (10 gpm).
3. Filter tank size calculated @ 407 lpm per m2 of bed area/10 gpm of backwash per square foot of bed area 4. Requires a V3158-02 installed for a brine elbow on the
control valve, use of a 454 controlled flow brine valve assembly H7070-36CF-5 or H7070-54CF-5 (designed with 5 gpm BLFC) , 1” air check, or 494 brine valve
assembly, and minimum 3⁄4” hard pipe PVC brine line.
www.wateq.co.uk
BACK TO INDEX PAGE
147
WATEQ SOUTH : 0203 744 5934
WATEQ NORTH : 0161 250 2040