Wateq 2023 - Flipbook - Page 145
CLACK VALVES
CLACK WS1.25 CI SOFTENER / FILTER VALVE
CLACK WS1.25 CI SPECIFICATIONS
Inlet/Outlet Fittings
¾" to 1 ½” NPS
Cycles
up to 9
Valve Material
Noryl (1) or equivalent
Regeneration
downflow
FLOW RATES
Service @ 15 psi/1 bar drop (includes bypass and meter)
129 lpm (7.7 m3/h) (34 gpm)
Backwash @ 25 psi/1.7 bar drop (includes bypass)
121 lpm (7.3 m3/h) (32 gpm) (2)
OPERATING PRESSURES
Minimum / Maximum
20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum / Maximum
40º - 110º F (4º – 43º C)
METER
Accuracy
± 5%
Flow Rate Range
0.95 - 129 lpm
Volume Range
0.02 - 5,700 m3
Totalizer
1 m3 - 99,999 m3
DIMENSIONS & WEIGHT
Distributor Pilot
1.32" OD Pipe (1" NPS) or 32 mm OD
Drain Line
¾” or 1” NPT
Brine Line
” or ½” OD Poly Tube
Mounting Base
2 ½” - 8 NPSM
Height From Top Of Tank
7 ” (187 mm)
Weight
4.5 lbs (2 kg)
ELECTRICAL SPECIFICATIONS
Supply Voltage
200VAC to 240VAC
Supply Frequency
50/60 Hz
Output Voltage
15VDC
Output Current
500 mA
TANK APPLICATIONS
Water Softener
6” – 21” diameter
Water Filter (2)
6” – 24” diameter
CYCLES OF OPERATION (SOFTENER DOWNFLOW)
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Cycle
Range of times minutes
Backwash
1 - 120 minutes
Rinse
1 - 120 minutes
Pause (service)
1 - 480 minutes
Brine (co-current)
1 - 180 minutes
Refill (softener)
0.05 - 90.00 Kg
Refill (filter)
0.2 - 76.00 Litres
Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentration of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate,
sodium bisulfite, chlorine and chloramines
1. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company 2. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area. 3. Filter tank size
calculated @ 10 gpm of backwash per square foot of bed area/407 lpm per square meter of bed area
www.wateq.co.uk